{"id":123,"date":"2016-12-23T20:21:15","date_gmt":"2016-12-23T13:21:15","guid":{"rendered":"http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/?page_id=123"},"modified":"2020-04-14T11:05:51","modified_gmt":"2020-04-14T04:05:51","slug":"gallary","status":"publish","type":"page","link":"http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/gallary\/","title":{"rendered":"Equipment"},"content":{"rendered":"<hr \/>\n<p><strong>Instron ElectroPuls E10000<\/strong>: an\u00a0electric fatigue machine designed for dynamic and static testing on a wide range of materials and components.<\/p>\n<ul>\n<li>Dynacell load cell: \u00b11 kN, \u00b15 kN and \u00b110 kN<\/li>\n<li>High-pressure pneumatic grip: \u00b110 kN fatigue-rated capacity with 0 to 12.7 mm flat serrated jaw faces\u00a0for rectangular\u00a0specimen and 3 to 18 mm Vee jaw faces for circular\u00a0specimen<\/li>\n<li>Bending fixtures (5 kN capacity) and clevis grips (10 kN capacity): fracture toughness test and fatigue\u00a0crack growth test<\/li>\n<li>Dynamic extensometer:\u00a012.5 mm gage length with \u00b15 mm travel\u00a0and\u00a00.01 mm accuracy<\/li>\n<li>Clip gage: 4 mm travel (6 to 10 mm) with 0.01 mm accuracy for\u00a0crack opening displacement<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-200\" src=\"http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-content\/uploads\/2016\/12\/instron_E10000-450x1024.jpg\" width=\"300\" height=\"683\" srcset=\"http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-content\/uploads\/2016\/12\/instron_E10000-450x1024.jpg 450w, http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-content\/uploads\/2016\/12\/instron_E10000-132x300.jpg 132w, http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-content\/uploads\/2016\/12\/instron_E10000.jpg 630w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<hr \/>\n<p><strong>Instron 5969<\/strong>: a dual column table top electromechanical testing system for static testing.<\/p>\n<ul>\n<li>Testing speed range: 0.001 to 600 mm\/min<\/li>\n<li>Static Load Cell: 1 kN, 5 kN and 50kN<\/li>\n<li>Wedge Action Grips:\u00a050 kN capacity with\u00a0 0 to 6.4\u00a0mm flat serrated jaw faces for rectangular specimen and 3.2 to 7.8\u00a0mm Vee jaw faces for circular specimen<\/li>\n<li>Strain Gauge Extensometer: 10 mm and 25 mm gage length with , \u00b150% maximum strain<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-209\" src=\"http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-content\/uploads\/2016\/12\/instron_E10000-1.jpg\" width=\"300\" height=\"524\" srcset=\"http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-content\/uploads\/2016\/12\/instron_E10000-1.jpg 630w, http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-content\/uploads\/2016\/12\/instron_E10000-1-172x300.jpg 172w, http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-content\/uploads\/2016\/12\/instron_E10000-1-586x1024.jpg 586w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<hr \/>\n<p><strong>CSM TRB-S-DE<\/strong>: a tribometer (ball-on-disc and pin-on-disc) for friction and wear evaluations.<\/p>\n<ul>\n<li>Friction\u00a0force measurement: up to 10 N<\/li>\n<li>Normal load: 1 to\u00a010 N<\/li>\n<li>Rotation speed: up to 500 rpm<\/li>\n<li>Ball and pin holders: 6 mm<\/li>\n<li>Testing conform: DIN 50324, ASTM G99 and ASTM G133<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-185\" src=\"http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-content\/uploads\/2016\/12\/pin_on_disc.jpg\" width=\"450\" height=\"340\" srcset=\"http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-content\/uploads\/2016\/12\/pin_on_disc.jpg 761w, http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-content\/uploads\/2016\/12\/pin_on_disc-300x227.jpg 300w\" sizes=\"auto, (max-width: 450px) 100vw, 450px\" \/><\/p>\n<hr \/>\n<p><strong>National Instrument DAQ<\/strong>: data acquisition system for various measurement devices<\/p>\n<ul>\n<li><strong>NI 9237 module<\/strong>: (x2) bridge\/strain measurement device<\/li>\n<li>24-bit resolution, \u00b125 mV\/V analog inputs<\/li>\n<li>4 simultaneously sampled analog inputs; 50 kS\/s\u00a0per channel\u00a0sampling rate<\/li>\n<li>Programmable quarter-, half- and full-bridge completion; up to 10 V internal excitation<\/li>\n<\/ul>\n<ul>\n<li><strong>NI 9219 module<\/strong>: (x2)\u00a0four-channel universal module (strain gages, RTDs, thermocouples, load cells, and other powered sensors)<\/li>\n<li>100 S\/s per channel sampling rate (50 S\/s per channel sampling rate for thermocouple)<\/li>\n<li>Built-in quarter-, half-, and full-bridge support for strain measurement<\/li>\n<li>Can perform a different measurement type on each of the four channels<\/li>\n<li>Measurement ranges differ for each type of measurement, and include up to \u00b160 V for voltage and \u00b125 mA for current<\/li>\n<\/ul>\n<ul>\n<li><strong>NI 9215 module<\/strong>: (x1) voltage input\u00a0measurement device<\/li>\n<li>\u00b110\u00a0V measuring range, 16-bit resolution<\/li>\n<li>4 differential channels, 100 kS\/s\u00a0per channel\u00a0sampling rate<\/li>\n<\/ul>\n<ul>\n<li><strong>NI 9213 module<\/strong>: (x1) temperature\u00a0measurement device<\/li>\n<li>16\u00a0differential channels for thermocouples,\u00a075\u00a0S\/s\u00a0per channel\u00a0sampling rate<\/li>\n<li>24-bit resolution, \u00b178 mV analog inputs<\/li>\n<li>Work\u00a0with\u00a0J, K, T, E, N, B, R, S thermocouple types (Up to 0.02 \u00b0C measurement sensitivity)<\/li>\n<\/ul>\n<ul>\n<li><strong>NI 9250 module<\/strong>: (x2) sound &amp; vibration measurement device<\/li>\n<li>2-Channel, 102.4 kS\/s\/ch simultaneous, \u00b15 V<\/li>\n<li>Work\u00a0with both integrated electronic piezoelectric (IEPE) and non\u2011IEPE sensors (such as accelerometers and microphones)<\/li>\n<\/ul>\n<ul>\n<li><strong>NI cDAQ-9174<\/strong>: (x1) 4\u2011Slot, USB compactDAQ chassis<\/li>\n<li><strong>NI cDAQ-9171<\/strong>: (x2) 1\u2011Slot, USB compactDAQ chassis<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-252\" src=\"http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-content\/uploads\/2016\/12\/DAQ-300x159.jpg\" width=\"450\" height=\"238\" srcset=\"http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-content\/uploads\/2016\/12\/DAQ-300x159.jpg 300w, http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-content\/uploads\/2016\/12\/DAQ-768x406.jpg 768w, http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-content\/uploads\/2016\/12\/DAQ.jpg 855w\" sizes=\"auto, (max-width: 450px) 100vw, 450px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Instron ElectroPuls E10000: an\u00a0electric fatigue machine designed for dynamic and static testing on a wide range of materials and components. Dynacell load cell: \u00b11 kN, \u00b15 kN and \u00b110 kN High-pressure pneumatic grip: \u00b110 kN fatigue-rated capacity with 0 to 12.7 mm flat serrated jaw faces\u00a0for rectangular\u00a0specimen and 3 to 18 mm Vee jaw faces &hellip; <\/p>\n<p class=\"link-more\"><a href=\"http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/gallary\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Equipment&#8221;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-123","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-json\/wp\/v2\/pages\/123","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-json\/wp\/v2\/comments?post=123"}],"version-history":[{"count":58,"href":"http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-json\/wp\/v2\/pages\/123\/revisions"}],"predecessor-version":[{"id":341,"href":"http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-json\/wp\/v2\/pages\/123\/revisions\/341"}],"wp:attachment":[{"href":"http:\/\/chaosuan.me.engr.tu.ac.th\/chaosuan\/wp-json\/wp\/v2\/media?parent=123"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}